Four-Tank Cleaning + Rinsing + Spray + Drying Line - view 4

Standard 1-Tank to 4-Tank Industrial Ultrasonic Cleaning, Filtration, Rinsing & Drying Systems

When scaling up from a benchtop bath to a floor-standing industrial ultrasonic parts cleaner or multi tank ultrasonic cleaner, selecting the right combination of recirculation oil filtration (`F`), immersion/ultrasonic rinsing (`R`), spray rinsing (`S`), and hot-air turbine drying (`D`) determines bath longevity and part cleanliness. This guide covers all eight standard Jietai `JTS` and `JTM` industrial modular series from 38 L up to 1,080+ L per tank.

1. Decoding Jietai Standard Industrial Model Nomenclature (S, F, D, FR, FRD, FRSD)

Every standard Jietai industrial tank is fabricated from 2.0 mm thick SUS304 (or optional SUS316L) stainless steel with external digital generators (JTF-28K Series). Adding a recirculation filtration loop (`F`) with a weir overflow oil skimmer and stainless canister housing (Filter Cotton Core) prevents emulsified cutting oil from re-contaminating parts as the basket is lifted out of the bath.

2. Complete 1-Tank to 4-Tank Standard Industrial Series Matrix

Series Code Standard Equipment Line Tank Count Process Stages Transducer & Power Range
JTS-1012S – JTS-1216S Single-Tank Ultrasonic Cleaning Series 1-Tank Ultrasonic wash (38 L to 1,080 L) 12 to 216 transducers (600 W – 10,800 W)
JTS-1012F – JTS-10216F Single Tank Ultrasonic Cleaning + Filtration System 1-Tank + Filter Ultrasonic wash + recirculation filtration + weir oil skimmer 600 W – 10,800 W (28 / 40 kHz)
JTM-2012D – JTM-20216D Dual Tank Ultrasonic Cleaning + Drying Series 2-Tank Ultrasonic wash + hot-air drying chamber 600 W – 10,800 W ultrasonic + hot air
JTM-2012FD – JTM-20216FD Double tank cleaning + Filtering + Drying series 2-Tank + Filter Ultrasonic wash (with filtration loop) + hot-air drying 600 W – 10,800 W ultrasonic + filtration
JTM-2024FR – JTM-20432FR Dual Tank Ultrasonic Cleaning+ Filtration + Rinsing Series 2-Tank Ultrasonic wash (with filtration) + ultrasonic/immersion rinse 1,200 W – 21,600 W total ultrasonic
JTM-3024FRD – JTM-30432FRD Triple Tank Ultrasonic Cleaning + Filtration + Rinsing + Drying Series 3-Tank Ultrasonic wash (with filtration) + ultrasonic rinse + hot-air drying 1,200 W – 21,600 W + turbine dryer
JTM-4024FRSD – JTM-40432FRSD Quadruple Tank Ultrasonic Cleaning + Filtration + Rinsing + Spray + Drying Series 4-Tank Ultrasonic wash (filtered) + ultrasonic rinse + spray rinse + drying 1,200 W – 21,600 W + spray + dryer
JTM-4036FRD – JTM-40648FRD Quadruple Tank Ultrasonic Cleaning + Filtration + Rinsing+ Rinsing + Drying Series 4-Tank Ultrasonic wash (filtered) + dual cascade ultrasonic rinse + drying 1,800 W – 32,400 W total ultrasonic

3. How to Choose Between 1-Tank, 2-Tank, 3-Tank, and 4-Tank Configurations

4. SUS304 / SUS316L Tank Construction, Transducer Bonding & Acoustic Power Sizing

In industrial production environments, the structural integrity of an ultrasonic cleaning tank directly governs cavitation uniformity and service life. Guangdong Jietai fabricates standard benchtop baths (0.8 L to 30 L across the JPS series) with stamped SUS304 stainless steel inner tanks, while floor-standing single-tank (JTS series) and multi-tank (JTM, JT, JTV, and JTW series) industrial lines utilize heavy-gauge argon-arc welded SUS304 or optional SUS316L stainless steel plates. The radiating surface where piezoelectric transducers are mounted undergoes precision surface preparation, stud welding, and high-strength epoxy bonding so acoustic energy transfers into the liquid bath without delamination under continuous thermal cycling between room temperature and 80 °C.

When sizing ultrasonic power for industrial tanks, relying on a fixed watts-per-liter rule across all tank volumes causes under-powering in small tanks and excessive surface cavitation in deep tanks. Benchtop chambers between 2 L and 30 L typically operate at higher volumetric density (20 W/L to 40 W/L) because the liquid depth is shallow (100 mm to 200 mm). As industrial tank volumes scale from 38 L up to 500 L or 1,000 L in multi-tank gantry lines, acoustic design shifts from bottom-only transducer mounting to combined bottom-and-sidewall transducer arrays or drop-in immersible ultrasonic vibration plates (JTP-1008S through JTP-1048S). Positioning transducers along vertical sidewalls ensures that tall workpieces—such as hydraulic barrels, injection mold cores, or stacked wafer cassettes—receive uniform cavitation across their entire vertical profile rather than only near the tank floor.

Each transducer bank is driven by independent external digital ultrasonic generators (JTF series, 900 W to 2,400 W per module) housed in ventilated electrical cabinets separated from the wet chemical zone. Separating the generator electronics from humid acid, alkaline, or hydrocarbon vapor atmospheres prevents circuit board corrosion and allows maintenance technicians to adjust current output and frequency sweep parameters directly from the front control panel.

5. Workpiece Basket Loading, Degassing & Recirculation Filtration Operating Protocol

Even a properly sized multi-tank ultrasonic cleaning line will produce inconsistent cleanliness if parts are stacked directly on the tank bottom or if dissolved air and floating oils are not managed during production shifts. Workpieces must always be suspended inside perforated or wire-mesh SUS304 stainless steel baskets (or dedicated fixture racks for optical lenses, silicon wafers, and fuel injectors) maintained at least 30 mm to 50 mm above the bottom radiating plate. Placing heavy steel molds or hydraulic cylinders directly onto the tank floor dampens transducer vibration, reflects acoustic standing waves back into the piezoelectric crystals, and accelerates cavitation erosion on the stainless steel weld seams.

Whenever a tank is filled with fresh tap water, deionized water, aqueous alkaline detergent, or hydrocarbon solvent, dissolved gases must be evacuated before precision parts are loaded. Running the ultrasonic bath (or engaging the degas mode on JPS multifunctional units and vacuum chambers on hydrocarbon systems) for 10 to 20 minutes coalesces dissolved micro-bubbles so they rise and vent from the liquid. Without degassing, dissolved air cushions the implosion of cavitation bubbles and leaves air pockets trapped inside blind tapped holes, ejector pin bores, and capillary channels.

During continuous degreasing of stamped hardware, machined castings, or automotive components, emulsified cutting fluids and tramp oils accumulate at the liquid surface. If parts are lifted straight up through a floating oil film, the oil re-deposits onto the freshly cleaned metal surfaces before rinsing. Integrating a weir overflow skimming trough, an oil-water separator, and a pump-driven recirculation filtration canister (using replaceable polypropylene filter cotton cores) continuously sweeps floating oils and suspended particulates out of the primary wash tank. In multi-tank JTM-FRD and JTM-FRSD configurations, pairing a filtered wash stage with counter-current overflow rinsing and turbine hot-air drying ensures that detergent surfactants and mineral ions are completely flushed prior to thermal dehydration.

6. Pre-Order Engineering Specification & Sample Verification Checklist

To configure either a standard catalog model or a non-standard customized multi-tank ultrasonic line at our Dongguan manufacturing facility, engineering and procurement teams should define five core process parameters before requesting a formal layout drawing and quotation:

  • Workpiece Geometry, Material & Batch Weight: Provide the maximum external dimensions (length × width × height in millimeters), wall thickness, alloy or substrate type (carbon steel, aluminum alloy, brass, tool steel, optical glass, or silicon wafer), and the target weight or piece count per basket load.
  • Contaminant Composition & Upstream Process: Specify whether parts carry neat mineral stamping oil, water-soluble CNC coolant, cerium oxide polishing slurry, rosin solder flux, polymer outgassing carbon, or lapping paste, as this dictates whether an aqueous alkaline line, an electrolytic mold cleaner, or a closed-loop hydrocarbon/vapor-phase system is appropriate.
  • Blind Holes, Internal Channels & Surface Sensitivity: Indicate the smallest internal bore diameter or slot width and whether polished or coated surfaces require dual-frequency switching (28/40 kHz), high-frequency optical rinsing (80/120 kHz), or 950 kHz megasonic acoustic streaming.
  • Drying & Rust-Prevention Requirements: Confirm whether downstream assembly or coating requires ambient air blow-off, rust-preventive passivation immersion, high-velocity air knives, hot-air circulation tunnel drying, rotary centrifugal spin drying, or vacuum drying.
  • Plant Utilities & Footprint Constraints: Note available factory floor length, ceiling clearance for overhead electric hoists or PLC gantry cranes, three-phase electrical supply specifications, and whether auxiliary pure water (RO+EDI), recirculating water chillers, or industrial wastewater treatment modules should be integrated into the turnkey line.

Frequently Asked Questions (FAQ)

How does the recirculation filtration and oil skimmer loop (F series) extend chemical bath life?

Floating tramp oil overflows into an auxiliary skimming chamber where a circulation pump pushes the fluid through replaceable polypropylene filter cotton cores before returning clean solution to the main ultrasonic tank, extending bath life by 3× to 5×.

What is the difference between the 4-tank JTM-FRSD and JTM-FRD (dual rinse) series?

The JTM-4024FRSD series uses Tank 3 for high-pressure spray rinsing before drying, whereas the JTM-4036FRD series uses two sequential ultrasonic immersion rinse tanks (Tank 2 and Tank 3) for counter-current dilution prior to Tank 4 drying.

What tank wall thickness is used in Jietai JTS and JTM industrial ultrasonic cleaners?

All floor-standing JTS and JTM industrial ultrasonic tanks use 2.0 mm thick SUS304 or SUS316L stainless steel plates with hard-chrome plated radiating surfaces for cavitation erosion resistance.

Recommended Jietai industrial ultrasonic systems for this process: 3-Tank Manual Ultrasonic Cleaning Machine (3), Ultrasonic Cleaning & Rotary Centrifugal Drying System for Aircraft Wheels (ULTRASONIC), Ultrasonic Cleaning & Drying System for Infrared Lens Glasses (ULTRASONIC), Ultrasonic Cleaning Machine with Electric Hoist Lifting (ELECTRIC).

Complete Ultrasonic Equipment, Category & Technical Guide Index
Frequently Asked Questions (Engineering & Selection FAQ)

How do we select between 28 kHz, 40 kHz, and 80–120 kHz ultrasonic frequency?

Use 28 kHz for heavy oils and cast iron or steel blocks, 40 kHz as the universal industrial standard for CNC machined aluminum and stainless steel parts, and 80–120 kHz or megasonic systems for optics, semiconductor wafers, and delicate electronics.

What tank volume and ultrasonic power density are required for batch cleaning?

Size the working liquid volume so the basket occupies no more than 65–70% of tank length and width, and maintain 10–15 W/L ultrasonic power density for general degreasing or 15–22 W/L for blind holes.

Which compliance standards do JieTai industrial ultrasonic cleaners meet?

JieTai ultrasonic cleaning systems are engineered with SUS304 and SUS316L stainless steel tanks and comply with CE, FCC, and RoHS directives for industrial export.

Contact Us Right Now